Szczegóły Produktu:
Zapłata:
|
Laser: | 940nm | Laser power: | Max 20 W |
---|---|---|---|
Serive: | After-sell / OEM / ODM | Wireless IC card management: | Yes |
RF frequency: | 10 MHz | Rollers speed: | 0-36rpm |
MB880 with 1 Year Warranty Vacuum slimming machine rf vacuum roller for salon use
Applications:
Body shaping, Body slimming, body circumference reduction, body contouring, weight loss, weight reduction, Cellulite Treatment, skin tightening, wrinkle removal; Skin surface smooth, massage, eyelid area treatment
a. Skin-tightening and wrinkle removal----The infrared light and radio frequency can heat up the target tissue in the deep layer of the skin for proliferating the collagen and improving the blood circulation to tighten the loose skin of face and eyes round and removal the wrinkles.
b. Body shaping----High Frequency radio can heat up the fattiness of 5-15mm, enhance the spread of oxygen molecules, and improve the cells material exchange, promote the fat metabolism, so the water and glycerin re-distribute; infrared light to increase the flexibility of the skin, under the protection of the skin, it heat subcutaneous fat; Mechanical rolling vacuum increase the blood supply, and promote the release of the enzymes during the metabolism of fat tissue.
c. Cellulite removal--- High frequency Radio frequency, which work together with the rolling vacuum suction can improve the blood circulation and increase the oxygen of the blood in targeted area. The lymphatic system will eliminate the waste and cure the fibrosis cellulite.
The heat can deep into the subcutaneous tissue to act the fibroblast of the connective tissue and restoring the collagen and elastic fibers.
1.5 Working Conditions
1) Environmental temperature for operation :10℃-30℃;
2) Environmental temperature for keeping: 0℃-50℃;
3) Relative humidity : ≤70%;
4) Air pressure : 860hPa~1060hPa;
5) Environment request : avoid direct radiation of intense light ;
6) To avoid intense light.
Note: If the temperature in the room is too low or the equipment has not been used for many days, you shall make the temperature of the host recover to 10℃ or higher before turning it on.
Functions of Handpiece and Default Parameters
Form 1: Functions of handpiece
Handpiece | Power of near-infrared laser | Speed of roller | RF energy | Negative pressure*Level | Pulse time *s |
Handpiece 1 | 0-20w | 0-36 rpm | 0~60J /c ㎡ | 1 ~9 | 1s~8s |
Handpiece 2 | 0~20w | NO | |||
Handpiece 3 | 0~10w | NO | 0~50J /c ㎡ | 1 ~7 | 1s~6s |
Handpiece 4 | NO | NO | 0~40J /c ㎡ | 1 ~6 | 1s~4s |
Form 2: Default parameters
Handpiece | Power of near-infrared laser | Speed of roller | RF energy | Negative pressure*Level | Pulse time *s |
Handpiece 1 | 14w | 18 rpm | 25J /c ㎡ | 3 | 3s |
Handpiece 2 | 14w | NO | 25J/c ㎡ | 3 | 3s |
Handpiece 3 | 6w | NO | 25J/c ㎡ | 1 | 2s |
Handpiece 4 | NO | NO | 20J /c ㎡ | 1 | 2s |
Form 3: Default handpiece for different body parts
Body parts | Default handpiece | Body parts | Default handpiece | Body parts | Default handpiece |
Belly | Calf | Face | HandPiece3 | ||
Back | Waist | Neck | |||
Thigh | HandPiece1 | Arm | HandPiece2 | Eyelid | HandPiece4 |
Advantages of the Machine:
- Bipolar Radio frequency (RF, 10MHz)Delivery: with the power of 50 w, penetrate the deeper skin up to 15mm, precisely controls the volume of tissue heated.
- Infrared light:to proliferate collagen, improve blood circulation, reached the good efficacy of whitening and flexibility.
- Mechanical rollers and vacuum suctionto manipulate the superficial fat tissue layer that contributes to cellulite, the heat from the light and RF energies increases metabolism of this fatty layer and shrinks the size of fat cells. The mechanical rollers and vacuum suction act on the blood vessels to increase circulation to the local area, as well as massaging the skin to achieve a smoother, less dimpled surface appearance.
- No Downtime:Innovative SynShape technology bypasses the epidermis so patients can immediately return to normal activities
- Easy:Intuitive touch screen interface with computerized treatment presets facilitates treatment for all users, from novice to experienced
- Safe: Vacuum assisted bipolar working head focuses RF energy precisely where it can have the maximum effect. Heat conduction to the epidermis and non-target tissue is minimized shape& Smooth features revolutionary combination of bipolar radio frequency, near infrared laser, endermologle, pulse mechanical tissue manipulation;
The safety and effectiveness of the technology and of the MB880 shape& Smooth system have been demonstrated in body contouring and wrinkle removal on any parts of human body;
MB880 shape& Smooth is the example of perfect combining ALUMA of American LUMENIS company with VELASHAPE of Israel Syneron company.
LED Screen | a) Main screen: 8" TFT Chromatic Touch Screen |
b) Screen of applicator | |
Screen of applicator 1: 2.4" | |
Screen if applicator 2: 1.9" | |
Vacuum | Pulse mode |
Absolute pressure | 80kpa-10kpa (60.8cmHg-7.6cmHg) |
Relative pressure | 20kpa-90kpa (15.2cmHg-68.4cmHg) |
Laser | 940nm |
Applicator tips | 4 |
Net weight | 60kg |
RF frequency | 10 MHz |
Rollers speed | 0-36rpm |
Laser power | Max 20 W |
Wireless IC card management | Yes |
Rollers working mode | 1 type |
Safety Testing Mode | Real-time online |
Energy Density of RF | Max 60J/ c m3 |
Rated input voltage | AC230±10%, 50Hz±1Hz/ |
AC110V±10%, 60Hz±1Hz (optional) | |
Treatment area of handpiece |
4mm*7mm/ 8mm*25mm/30mm*50mm/40mm*60mm |